Vortex
Tubes are devices that work on a standard compressed air supply.
Air enters the vortex tube and literally splits the air flow
into two parts - cold air at one end, and hot air at the other
- all without any moving parts.
Vortex Tubes have an adjustable valve at the "hot"
end controls the volume of the air flow, and the temperature
exiting at the cold end. By adjusting the valve, you control
the "cold fraction" which is the percentage of total
input compressed air the exists the cold end of the vortex
tube.
Inside is the interchangeable "generator" which
can alter the air used in the vortex tube, and control the
temperature ranges you wish to have at the cold and hot ends.
There are several ranges of generators for compressed air
capacity. There are also two basic types of generators - one
to produce the extreme cold temperatures (maximum cold temperature
out called the C generator) and one type to produce the maximum
amount of cooling (maximum refrigeration called the H generator).

Nex
Flow Frigid-X Products Are Best Because...
Frigid-X
Vortex Tubes are constructed of stainless steel and use a
generator and valve made of brass and sealed with viton o-rings
to allow their use in the widest range of environments. Others
use plastic generators and standard buna N o-rings and charge
extra for brass and viton. The unique design and quality of
materials used in Nex Flow
products will deliver years of maintenance-free operation.
Advantages
-
No moving
parts, reliable, maintenance free
-
-
-
-
-
Instant
cold air in environmental chambers
-
No spark
or explosion hazard
-
Interchangeable
generators
Aplications
They
are used in the following applications.
-
Cool
electronic and electrical controls
-
Cool
machine operations/tooling
-
-
-
-
-
-
Cooling
environmental chambers
How Do They
Work

Compressed air, typically at
80-to 100 PSlG enters from the side at a tangent and enters
through the generator into the tube, causing the air to spin.
This air stream spins toward the hot end where some leaves
the tube via the control valve. The remaining, spinning air
travels back up the center of the tube. The inner spinning
stream gives off heat energy to the outer stream (which leaves
at the hot end as hot air) and exits at the cold end as cooled
air. The input air is literally split into hot and cold using
no moving parts.
Setting Flow
and Temperature in a Vortex Tube
Adjusting the slotted valve at the hot air outlet sets the
flow rate and temperature at the cold end. The more air let
out at the hot end reduces the cold air flowing and the cold
air temperature at the cold end. Close the valve at the hot
end and you increase the cold air flow at the cold end as
well as the air temperature at the cold end. The percentage
of total input air to the vortex tube that is directed to
the cold end is the "cold fraction". A cold fraction
of 60% to 80% produces the optimum refrigeration, or Btu/hr.
See the chart below which indicates the temperature
"rise" at the hot end and temperature "drop"
at the cold end of a vortex tube at various input pressures
(PSIG) and "cold Fraction" setting.
Most industrial applications, such as electrical control panel
cooling, parts cooling, tool cooling require maximum refrigeration
and utilize the Nex Flow Frigid-X 5000H series.
Applications which require extreme cold temperatures such
as lab sample cooling, circuit board testing, would utilize
the Nex Flow Frigid-X5000C series. However,
mufflers are available for both the cold and hot ends if required.
Specifications
|
Model
#
|
SCFM
@100 PSIG inlet
|
Btu/hr.
at 100 PSIG
|
Size
|
|
50002H
|
2
|
145
|
small
|
|
50004H
|
4
|
290
|
small
|
|
50008H
|
8
|
580
|
small
|
|
50010H
|
10
|
730
|
medium
|
|
50015H
|
15
|
1100
|
medium
|
|
50025H
|
25
|
1800
|
medium
|
|
50030H
|
30
|
2100
|
medium
|
|
50040H
|
40
|
2900
|
medium
|
|
Model
#
|
SCFM
@100 PSIG inlet
|
For
Cold Temperature
|
Size
|
|
50002C
|
2
|
----
|
small
|
|
50004C
|
4
|
----
|
small
|
|
50008C
|
8
|
----
|
small
|
|
50010C
|
10
|
----
|
medium
|
|
50015C
|
15
|
----
|
medium
|
|
50025C
|
25
|
----
|
medium
|
|
50030C
|
30
|
----
|
medium
|
|
50040C
|
40
|
----
|
medium
|
Approximate temperature
drops (and rises) from inlet air temperature produced by a vortex
tube set at various cold fractions. Assume constant inlet pressure
and temperature.
| Temperature drop of cold
air, °F in blue |
Temperature rise of hot
air , °F in red |
|
Pressure
Supply
|
Cold
Fraction %
|
|
PSIG
|
|
20
|
|
0
|
|
40
|
|
0
|
|
60
|
|
0
|
|
80
|
|
0
|
|
100
|
|
0
|
|
120
|
|
|
|
20
|
30
|
40
|
50
|
60
|
70
|
80
|
|
62
|
60
|
56
|
51
|
44
|
36
|
28
|
|
15
|
25
|
36
|
50
|
64
|
83
|
107
|
|
88
|
85
|
80
|
73
|
63
|
52
|
38
|
|
21
|
35
|
52
|
71
|
92
|
117
|
147
|
|
104
|
100
|
93
|
84
|
73
|
60
|
46
|
|
24
|
40
|
59
|
80
|
104
|
132
|
166
|
|
115
|
110
|
102
|
92
|
80
|
66
|
50
|
|
25
|
43
|
63
|
86
|
113
|
143
|
180
|
|
123
|
118
|
110
|
100
|
86
|
71
|
54
|
|
26
|
45
|
67
|
90
|
119
|
151
|
191
|
|
129
|
124
|
116
|
104
|
91
|
74
|
55
|
|
26
|
46
|
69
|
94
|
123
|
156
|
195
|
|
For larger clearer view download
pdf file by clicking on picture above.