Frigid-X™
Vortex Tubes are devices that work on a standard compressed
air supply. Air enters the vortex tube and literally splits
the air flow into two parts - cold air at one end, and hot air
at the other - all without any moving parts.
Vortex Tubes have an adjustable valve at the "hot"
end controls the volume of the air flow, and the temperature
exiting at the cold end. By adjusting the valve, you control
the "cold fraction" which is the percentage of total
input compressed air the exists the cold end of the vortex tube.
Inside is the interchangeable "generator" which can
alter the air used in the vortex tube, and control the temperature
ranges you wish to have at the cold and hot ends. There are
several ranges of generators for compressed air capacity. There
are also two basic types of generators - one to produce the
extreme cold temperatures (maximum cold temperature out called
the C generator) and one type to produce the maximum amount
of cooling (maximum refrigeration called the H generator).
Frigid-X
Vortex Tubes Are Best Because...
Frigid-X Vortex Tubes
are constructed of stainless steel and use a generator and valve
made of brass and sealed with viton o-rings to allow their use
in the widest range of environments. Others use plastic generators
and standard Buna N O-Rings and charge extra for brass and viton.
The unique design and quality of materials used in Frigid-X
products will deliver years of maintenance-free operation.
Frigid-X
Vortex Tubes Advantages
-
No moving
parts, reliable, maintenance free
-
-
-
-
-
Instant
cold air in environmental chambers
-
No spark
or explosion hazard
-
Interchangeable
generators
Frigid-X
Vortex Tubes Applications
They are used
in the following applications.
-
Cool electronic
and electrical controls
-
Cool machine
operations/tooling
-
-
-
-
-
-
Cooling
environmental chambers
How Do They
Work
Compressed air, typically at
80-to 100 PSlG enters from the side at a tangent and enters
through the generator into the tube, causing the air to spin.
This air stream spins toward the hot end where some leaves the
tube via the control valve. The remaining, spinning air travels
back up the center of the tube. The inner spinning stream gives
off heat energy to the outer stream (which leaves at the hot
end as hot air) and exits at the cold end as cooled air. The
input air is literally split into hot and cold using no moving
parts.
Setting Flow
and Temperature in a Frigid-X
Vortex Tubes
Adjusting the slotted valve at the hot air outlet sets the flow
rate and temperature at the cold end. The more air let out at
the hot end reduces the cold air flowing and the cold air temperature
at the cold end. Close the valve at the hot end and you increase
the cold air flow at the cold end as well as the air temperature
at the cold end. The percentage of total input air to the vortex
tube that is directed to the cold end is the "cold fraction".
A cold fraction of 60% to 80% produces the optimum refrigeration,
or Btu/hr. See the chart below which indicates
the temperature "rise" at the hot end and temperature
"drop" at the cold end of a vortex tube at various
input pressures (PSIG) and "cold Fraction" setting.
Most industrial applications, such as electrical control panel
cooling, parts cooling, tool cooling require maximum refrigeration
and utilize the Nex Flow Frigid-X 5000H series.
Applications which require extreme cold temperatures such as
lab sample cooling, circuit board testing, would utilize the
Nex Flow Frigid-X5000C series. However,
mufflers are available for both the cold and hot ends if required.
Frigid-X
Vortex Tubes Specifications
| Model
# |
SCFM
@100 PSIG inlet |
Btu/hr.
at 100 PSIG |
Size |
| 50002H |
2 |
145 |
small |
| 50004H |
4 |
290 |
small |
| 50008H |
8 |
580 |
small |
| 50010H |
10 |
730 |
medium |
| 50015H |
15 |
1100 |
medium |
| 50025H |
25 |
1800 |
medium |
| 50030H |
30 |
2100 |
medium |
| 50040H |
40 |
2900 |
medium |
| Model
# |
SCFM
@100 PSIG inlet |
For
Cold Temperature |
Size |
| 50002C |
2 |
---- |
small |
| 50004C |
4 |
---- |
small |
| 50008C |
8 |
---- |
small |
| 50010C |
10 |
---- |
medium |
| 50015C |
15 |
---- |
medium |
| 50025C |
25 |
---- |
medium |
| 50030C |
30 |
---- |
medium |
| 50040C |
40 |
---- |
medium |
Approximate temperature
drops (and rises) from inlet air temperature produced by a vortex
tube set at various cold fractions. Assume constant inlet pressure
and temperature.
| Temperature drop of cold
air, °F in blue |
Temperature rise of hot
air , °F in red |
| Pressure
Supply |
Cold
Fraction % |
| PSIG |
| 20 |
| 0 |
| 40 |
| 0 |
| 60 |
| 0 |
| 80 |
| 0 |
| 100 |
| 0 |
| 120 |
 |
|
| 20 |
30 |
40 |
50 |
60 |
70 |
80 |
| 62 |
60 |
56 |
51 |
44 |
36 |
28 |
| 15 |
25 |
36 |
50 |
64 |
83 |
107 |
| 88 |
85 |
80 |
73 |
63 |
52 |
38 |
| 21 |
35 |
52 |
71 |
92 |
117 |
147 |
| 104 |
100 |
93 |
84 |
73 |
60 |
46 |
| 24 |
40 |
59 |
80 |
104 |
132 |
166 |
| 115 |
110 |
102 |
92 |
80 |
66 |
50 |
| 25 |
43 |
63 |
86 |
113 |
143 |
180 |
| 123 |
118 |
110 |
100 |
86 |
71 |
54 |
| 26 |
45 |
67 |
90 |
119 |
151 |
191 |
| 129 |
124 |
116 |
104 |
91 |
74 |
55 |
| 26 |
46 |
69 |
94 |
123 |
156 |
195 |
|
For larger clearer view download
pdf file by clicking on picture above.