General Carbon Corp., J Series Liquid Phase Adsorbers


The General | FRP-Series | TL-Adsorbers | J-Series

General,Carbon,Corp.,J Series,Liquid,Phase,AdsorbersJ Series Liquid Phase Adsorbers

General Carbon Corp., J Series Liquid Phase Adsorbers are ideal for liquid treatment applications where higher pressures must be dealt with.

All General Carbon Corp., J Series Liquid Phase Adsorbers units are built to 100 psi standards and are designed for long term installation.

General Carbon Corp., J Series Liquid Phase Adsorbers units have two part Epoxy coatings on the inside and industrial enamel on the outside.

Standard General Carbon Corp., J Series Liquid Phase Adsorbers units have PVC internals, two access ports, a vent connection in the top and steel FPT fittings and legs.

Easy access to the carbon allows for on site carbon service and the economy of bulk carbon usage. GC 8x3O or GC 12x40 coal base carbon is standard with reactivated GC 8x30R and other specialty carbons available upon request.



Specifications

Model No. 

Flow  
C#2   
EBCT3 

A

B

C 

D 

E 

F

G

 J-24
15 gpm
 300
 5.3 Min
 24"
 76"
 60"
4"x6"
2" 
2" 
2"4
J-30
24 gpm
 450   
 5.0 Min
 30" 
 80" 
 60" 
11"x15" 
2" 
2" 
2"4
J-36
35 gpm
 560
 4.3 Min 
 36" 
 83"
 60" 
1 1"x15" 
2" 
2" 
2"4
J-42
48 gpm
 840
 4.7 Min 
 42" 
 83"
 60" 
1 1"x15" 
  3"
 3"
2"
J-42L
48 gpm
 1065
 5.9 Min 
 42" 
 95"
 72"
1 1"x15" 
  3"
 3"
2"
J-48
62 gpm
 1120
 4.9 Min
 48" 
 85"
 60" 
1 1"x15" 
  3"
 3"
3"
J-48L
62 gpm
 1400
 6.0 Min 
 48" 
 97"
 72"
1 1"x15" 
  3"
 3"
3"

1 Flow Rate at Maximum Recommended Loading of 5 gpm/sq ft Bed Cross Section Area
2 Pounds of Carbon is for Density of 28#/cu ft and allowing 50% Bed Expansion for Backwash. 3 Empty Bed Contact Time for given maximum flow.
4 Drain Option Available Upon Special Order. Standard for J-42 and J-48 models.

Installation & Start Up
J-Series adsorbers are shipped empty along with the required carbon. The adsorber should be connected and all fittings pressure tested for leaks before the carbon is installed through the top access hole. After the carbon has been loaded, the unit should be filled with clean water through the bottom collector, and allowed to degas for 812 hours if possible. Backwashing the carbon is recommended to remove carbon fines that can cause excessive pressure drop through the unit. Multiple units are usually connected in series with testing between the units advised to determine when the first unit needs to be changed out.

Maintenance
The only maintenance J-Series adsorbers require is the testing of effluent quality, and checking the operating pressure of the system. Monitoring the contaminant level into the last unit in a series arrangement is the recommended safeguard against having breakthrough in the final outflow. When the concentration of contaminants in the flow coming out of the lead unit equals the concentration of the flow into the unit, the unit has reached its removal capacity and needs to be serviced. The working life of carbon is dependent upon the type of contaminant in the water as well as its concentration and the liquid flow rate. A pressure relief device is advised to prevent damage to the system in the event of excessive pressure buildup. Backwashing an adsorber that is operating at an elevated pressure will sometimes provide a temporary lowering of the pressure drop through the unit.


Servicing J Tanks
Once an adsorber's carbon is saturated by contaminants, the unit should be taken off line and fresh carbon installed. To purchase replacement carbon or to arrange for a carbon change out, please contact our office. When preparing the unit for servicing, as much water as possible should be drained from the vessel.

Disposal
If you change the carbon out yourself, please dispose of the spent carbon in accordance with Federal, State and Local regulations.

Available Options
Custom features are available for special needs. ASME Section VIII Code Stamp, Stainless Steel tanks and/or internals, food grade or severe service coatings inside or out, custom sizes for space limitations and different connection locations for hookup to existing plumbing are routine requests. Please call us with your needs.

WARNING!
Wet activated carbon readily absorbs free oxygen. ANY carbon vessels requires that procedures confined space entry and oxygen depletion be followed!


Filter Innovations Inc
ACTIVATED CARBON FILTRATION SYSTEMS
Introduction
AIR PHASE CARBONS
Air Phase Carbons
F Series Adsorbers
ES Series Adsorber
ET Series Adsorbers
The General
TV Series Adsorbers
LIQUID PHASE CARBONS
Liquid Phase Carbons
FRP Series Adsorbers
J Series Adsorbers
The General
TL Series Adsorbers
AMIAD FILTRATION SYSTEMS
Automatic Filter Systems
ABFL Automatic Filters
EBF Automatic Filters
SAF Automatic Filters
TAF Automatic Filters
Plastic Water Filters & Strainers
Steel Water Filters & Strainers

Visit Filter Innovations Web Site


FILTER
INNOVATIONS
INC.
744 Gordon Baker Rd
Toronto ON M2H 3B4
Tel: 416 490-7848
Fax: 416 490-0974

General Carbon Corp., J Series Liquid Phase Adsorbers