MTL4000 SERIES
Isolating IS Interface Units

For close integration of IS circuits into process-connected systemsMTL4000,SERIES,isolating,IS,interface,units

  • Compact modular design with 'plug-in' connections
  • High packing density without loss of single-loop integrity
  • System backplane with bussed power and safe-area connections
  • Custom-designed backplanes for closest integration into process-connected systems
  • Reduced system engineering and installation costs
  • Range of standard enclosures protected to IP65
  • Modules certified internationally for equipment and wiring in all zones and explosive atmospheres
The MTL4000 Series of 'third-generation' isolating interface units introduces new concepts for integrating intrinsic safety into large or medium sized process-connected systems. Being exceptionally compact, the units give high packing densities without sacrificing single-loop integrity. Units plug into system backplanes with safe-area connections made by multiway connectors - an approach which not only simplifies engineering but also reduces installation and maintenance costs.

Modules handle the majority of applications covering on/off or analogue signals between hazardous-area equipment and safe-area systems. Modules incorporate proven intrinsically safe isolation techniques internationally certified for protecting equipment and wiring in all zones and explosive atmospheres.

Key module design features include a multiway connector on the base of each unit which mates with a connector on the backplane to provide both safe-area and power supply connections. Hazardous-area connections are made by a single connector which plugs into the top of the module. These connectors are available with either screw-clamp terminals or crimp connectors. This use of removable connectors greatly simplifies installation and maintenance, so reducing time, cost, and the risk of errors.
Status LEDs, configuration switches and ports are located on the tops of individual modules for easy access.


The compact design (modules are only 16mm wide) reduces weight and gives exceptionally high packing densities.

Based on proven IS isolation technology, MTL4000 Series modules do not need a high integrity earth and the associated circuits can be left floating or be earthed at any one point. With the exception of switch/proximity detector inputs, all modules provide single-loop integrity to maximise system security.

Line fault detection (LFD) facilities are provided on the MTL4014/4015/4016/4017 switch/proximity detectors, the MTL4023 solenoid/alarm driver and the MTL4045B 4/20mA isolating driver.

System backplanes are located in safe areas and, since the hazardous-area circuits are connected directly to the modules, do not need to be certified.

Data Sheet

Information Request Form


First Name
Last Name
Title
Company
Address
City
Province/State
Postal/Zip Code
Telephone Area Code -
Fax Area Code -
E-mail

I would like more information on the following:


Thank you
MTL Canda Safety Instrumentation
HAZARDOUS AREA DISPLAYS
Digital Indicators
Hazardous Area Displays
IS Digital Indicators
IS Text Displays
Process PC's
INTRINSIC SAFETY BARRIERS AND ISOLATORS
Choosing The Right Barrier
Intrinsic Safety Instrumentation
Isolators
MTL700
MTL2000
MTL3000
MTL4000
MTL4700
MTL5000
MTL7000
PROCESS I/O
What is Process I/O
MTL8000
SURGE PROTECTION
LC 30
SD Series
TP 48
OTHER PRODUCTS
Distributed I/O Systems
Earthing and Bonding
Fieldbus Comparision
HART Connection System
Multiplexer Systems
Explosion Protection
MTL Canada Safety
Instrumentation
20 REGAN RD
BRAMPTON ON L7A 1C3
Tel: 905 840 7850
Fax: 905 840 7852
MTL4000 SERIES isolating IS interface units