MTL4700 SERIES
Shunt-diode safety barriers

For close integration of IS circuits into hazardous-area measurement and
control circuitsMTL4700,Shunt-diode,safety,barriers

  • Ultra-high packing density provided by compact multichannel modules
  • Reduced system engineering/installation costs thanks to 'plug-in' connections
  • High-integrity earth connections
  • Customised backplanes need no certification from most certifying authorities
  • BASEEFA, FM, CSA and VNIIVE approved
The MTL4700 Series of 'third-generation' safety barriers are multi-channel devices designed for close integration of intrinsic safety into process systems. Combining the compact 'plug-in' design concept of the MTL4000 Series of isolators with the circuit designs of the well-known MTL700 Series of barriers, the new barriers provide exceptionally high packing densities allied to proven reliability - so reducing space requirements and weight loading without sacrificing performance. MTL4700 Series barrier modules plug into system backplanes to make safe-area connections while hazardous-oreo connections are made by separate connectors plugged into the tops of modules - an approach that both simplifies system design and reduces installation and maintenance costs.

The range includes five 'key' models which cover between them the majority of all process control requirements - so simplifying barrier selection for most purposes while still providing additional choices for applications not covered by the 'key' barriers.

Module features include a multiway connector on the base of each unit which mates with a connector on the backplane to bring out safe-area circuits, to provide system earthing and (on some backplanes) to feed bussed power to particular modules. The all-important high-integrity earth connections are made automatically by three pins in parallel on the base connection. Hazardous-area connections are made by a single connector which plugs into the top of the module - simplifying installation and maintenance to reduce time, cost and the risk of errors. These are available with either screw-clamp or crimp terminals. Modules are exceptionally compact (only 16mm in width) and multi-channel - giving the high packing density and low 'weight/ channel' ratio.

Standard backplanes are available in 8-, 16 and 24-way configurations with alternative choices of multiway or screw-clamp safe-area circuit connections and alternative means of providing power to the modules (by 'bussed-power' or 'general-purpose' backplanes). The accessories include a range of enclosures to accommodate 8- and 16-way backplanes. To maintain maximum system flexibility, modules suited to bussed power can generally also be used on general-purpose backplanes and vice versa.

Custom backplanes
Apart from the standard range, customised backplanes to suit particular system architectures are easy to design, either by MTL or by users, as the backplanes carry no hazardous-area circuits, so avoiding some design constraints and avoiding the need for expensive and time-consuming certification procedures.

References. The following documents ore available for further information on MTL4700 Series barriers:

AN9014 A user's guide to MTL4700 Series safety barriers
INM4700 MTL4700 Series shunt-diode safety barriers instruction manual.

Data Sheet

Information Request Form


First Name
Last Name
Title
Company
Address
City
Province/State
Postal/Zip Code
Telephone Area Code -
Fax Area Code -
E-mail

I would like more information on the following:


Thank you
MTL Canda Safety Instrumentation
HAZARDOUS AREA DISPLAYS
Digital Indicators
Hazardous Area Displays
IS Digital Indicators
IS Text Displays
Process PC's
INTRINSIC SAFETY BARRIERS AND ISOLATORS
Choosing The Right Barrier
Intrinsic Safety Instrumentation
Isolators
MTL700
MTL2000
MTL3000
MTL4000
MTL4700
MTL5000
MTL7000
PROCESS I/O
What is Process I/O
MTL8000
SURGE PROTECTION
LC 30
SD Series
TP 48
OTHER PRODUCTS
Distributed I/O Systems
Earthing and Bonding
Fieldbus Comparision
HART Connection System
Multiplexer Systems
Explosion Protection
MTL Canada Safety
Instrumentation
20 REGAN RD
BRAMPTON ON L7A 1C3
Tel: 905 840 7850
Fax: 905 840 7852
MTL4700 SERIES Shunt-diode safety barriers