Dynamic,Eco,Descaler

Dynamic Eco-Descaler


Products
by Category:

 ACCUTHERM HEATERS
  Air Heaters
  Bore Heaters
  Container Heaters
  Custom Heaters
  Immersion Heaters

  Tubular Elements
 BALERS
  
2-Ram Baler
  
Auto Tie Baler
  
Closed Door Horizontal
  Dust & Can Baler
  Expanado Hopper Baler
  Heavy Duty Vertical Baler
  Scrap Metal Vertical Baler
 BIODEGRADABLE PAINT
 STRIPPER

  JEM Strip 427

 BRIQUETTING MACHINES
  
Briquetters
  
Briquette Pellet Press
  
Briquetting Process
  Elan B60
  Elan Hydrospeed
 CHEMICAL PRODUCTS
  
Chemical Products
 COATINGS - WATER BASED
  
Carbicote Strippable Coating
 CONCRETE & ASPHALT
 CLEANER
  
Concrete & Asphalt Cleaner
 CORONA TREATMENT
  Flexidyne
  Labdyne
  Multidyne
  Polydyne
 DESCALERS & CLEANERS
  Cleaners
  Degreasers
  Descalers
 EXAIR COMPRESSED AIR

  Adjustable Spot Cooler

  Amplifier Products
  Air Knives
  Air Jets & Nozzles
  Air Operated Conveyors
  Cabinet Coolers
  Industrial Housekeeping
  Vortex Tubes
 EXAIR STATIC CONTROL
  Ion Air Cannon
  Ion Air Gun
  Ion Air Jet
  Ionizing Bars
  Ionizing Point
  Standard Ion Air Knife
  Static Eliminator Basics
  Static Eliminators
  Static Meter
  Super Ion Air Knife
 HAUG STATIC CONTROL
  Haug Charging Generators
  Haug High V Transformers
  Haug Ionization Bar
  Haug Ionizers
  Haug Ionization Systems
  Haug Ionizing Air Blower
  Haug Ionizing Air Gun
  Haug Ionizing Air Bar EI-VS
  Haug Ionizing Air Bar EI-Ex
  Haug Static Elimination
  Haug Static Measuring
  Haug Static Testing
  Haug Uno Air Gate

 HEAT TRANSFER FLUIDS
  Systems
  Food Grade
  High Quality
  Low Pressure
 HOT STAMPING MACHINES
  Automated Assembly Sys.
  Heat Transfer Decorating
  Hot Stamping Machines
  OIL SKIMMERS
  
Adjustable Lift Rate
  
Belt Type
  
"MAXI-Skimmer"
  "MINI-Skimmer"
  Tube Type
  Wheel Type

 PLASTIC FALW REPAIR
  Plastic Flaw Repair Products
 PRINTING PRESS EQUIP.
  Registration Control
  High Speed Card Insertion
  Variable Applicators
  Video Web Inspection
  Hurletron - Product Overview
 ROLL HANDLING SYSTEMS
  Reel Handlers
  Tilt-Lock - Core Chucks
  Tilt Lock - Systems
 ULTRASONIC CLEANING

  Ultrasonic Cleaning
  Mould Cleaners
 WASTE COMPACTION
  Kenbay


.

  Dynamic Eco-Descaler Biodegradeable

DYNAMIC ECO-DESCALER

Why use DYNAMIC ECO-DESCALER?


Before

After

It is a safe non-toxic, biodegradable chemical to be used on the waterside of heat transfer equipment.

You do not have to heat DYNAMIC ECO-DESCALER.

DYNAMIC ECO-DESCALER is safer for the employees to use than other acid products.

Your equipment will be cleaned in only hours without disassembling any part of the equipment. Equipment can also be cleaned without any down time (cleaning on the run).

Cleans down to the original surface without pitting.

DYNAMIC ECO-DESCALER is safe on copper, copper-nickel, bronze, brass, iron and rubber.

DYNAMIC ECO-DESCALER will extend the usable life of your equipment, especially when used as a part of a regularly scheduled preventative maintenance program.

Removing the scale build up allows your equipment to operate more efficiently with less down time.

DYNAMIC ECO-DESCALER is used buy Ford Motor Company, General Motors, Rubbermaid, Dow Chemical, USX, Dayton Tire, Baker Hugh, Kennametal, Allegheny Power Systems and many others in the U.S. and worldwide.

  Industry Use Of DYNAMIC ECO-DESCALER
Automotive
Closed Circuit Cooling, Dynamometers, Extruders, Molders and Radiators
Bottling
CO2 Generators, Heaters, Exchangers, Rinse Tanks, Sterilizers and Washers
Chemicals
Dryers, Extruders, Kettles, Mixers, Reactors, Scrubbers and Vacuum Pumps
Food
Condensers, Ice Machines, Kathabars, Refrigeration Equipment, Steam Tables
Manufacturing
Chillers, Compressors, Furnaces, Quenchers and Vacuum Pumps
Metals

Bearings, Conveyors, Filters, Presses, Process Lines and Radiators
Mining

Bearings, Conveyors, Filters, Presses, Process Lines, Radiators
Paper

Calendar Mill Rolls, Caustic Lines, Scrubbers, Compressors, Liquor Tanks, Pulverizers and Vacuum Pumps
Pharmaceutical
Exchangers, Loop Systems, Kathabars, Pumps, Reactors, Stills, Sterilizers
Refinery

Compressors, Converters, Crackers, Exchangers, Piping and Pumps
Rubber & Plastics
Banbury Mixers, Calendar & Mill Rolls, Extruders, Injection Molders, Molds, Temperature Control Units. Throat Coolers, Towers and Tubers

Steel

Bearings, ConCast Units, Generators, Hearths, Spangle Units and Furnaces

Textile

Air Washers, Compressors, Condensers, Exchangers, Extruders and Towers

 
  Air Compressors

A Reciprocating Compressor is normally a heavy-duty, continuous-service compressor. Cylinder construction usually incorporates a water jacketed cylinder and water jacketed heads to remove some of the heat of compression and also to improve the lubrication and reduce carbonization of valve parts. Water jacketing around valve and packing is essential, since these are points of localized heating.
As time goes on, you will have lime, water scale and rust accumulation inside the water jackets, which in time, will overheat the air compressor. This will also occur in the intercooler and aftercooler. With DYNAMIC ECO-DESCALER you can clean these vital parts, without disassembling the cylinders, aftercooler, and the intercooler. Just simply remove the water in/out connection from each part and circulate DYNAMIC ECO-DESCALER for the recommended amount of time. After the circulation, flush with water and connect the water in/out connections back to the proper location.

If your compressor is running off a closed loop water system or a cooling tower, you may want to pour the DYNAMIC ECO-DESCALER into one of these systems. This will eliminate the down time in your plant operation verses disconnecting your in/out connections from each vital part. Before you proceed with these operations contact the nearest distributor in your area, so they may be of assistance to you.
 

  Vacuum Pumps

In order to remove the water scale, lime, mud, and rust from the casting, rotor, hub, cones and associated piping of your equipment, the following instructions should be used.

1. Write down the "before" amperage readings, cfm at vacuum capacity and the vacuum in inches of mercury.

2. Take unit out of service.

3. Remove the bottom drain plug and allow all water to drain from pump casing.
Replace bottom plug after the unit is drained.

4. Break seal on water piping and attach a pumping discharge hose.

5. Remove top plug and attach return hose between there and the recirculating
bucket.

6. Insert "blanks" in flanges of discharge and suction piping.

7. Add prescribed quantity of DYNAMIC ECO-DESCALER into the circulation loop.

8. In some instances, additional water may be required to maintain circulation.

9. Tighten vacuum pump seal packing to minimize leakage.

10. After 15 minutes of DYNAMIC ECO-DESCALER circulation, turn pump rotor 90 degrees by pulling on the drive belts or jacking the starter switch.

11. Every 15 minutes thereafter, turn rotor 90 degrees to assure a thorough cleaning of interior parts of your pump, including hub and rotor.

12. Continue the circulation of DYNAMIC ECO-DESCALER for at least two hours or until the foaming stops. Lack of foam indicates depleted or clean equipment.

13. After several hours of circulation time, with intermittent turning of the rotor, the pump should be clean and rotor should turn freely.

14. Shut off the circulating pump and add flush water to the recirculation bucket.

15. Disconnect return hose and run to drain.

16. Restart circulation pump and flush until water runs clear.

17. Disconnect pump and all hoses. Remove all the "blanks" in the flanges and
reconnect all piping.

18. Open seal water valve, start the vacuum pump and operate for 10-20 minutes to thoroughly flush the pump. During this time adjust the seal water rate to the
manufacturers recommendations. Also readjust the packing compression to
the correct setting.

19. Return pump to service.

20. After unit has stabilized, write down the "after" amperage readings, cfm at
vacuum capacity and vacuum in inches of mercury.

21. Compare the "before" and the "after" readings to determine the effectiveness of DYNAMIC ECO-DESCALER cleaning. Record all information for future reference to schedule next preventative maintenance cleaning.
 

  Cooling Towers & Closed Circuit Cooling

DYNAMIC ECO-DESCALER cleaning of cooling towers and closed circuit water cooling systems is most usually accomplished while the water cooled equipment is online and without the necessity of shut-down. In order to dissolve all water scale, lime, rust and dirt from the water side of your equipment, it is imperative that these instructions are followed.

INSTRUCTIONS FOR DYNAMIC ECO-DESCALER CLEANING

1. While units to be cleaned are in operation or merely connected with water flowing to them, shut off make-up water and bleed-off to tower and/or sump tank.

2. Open drain valve in bottom of sump tank and lower the water level to a point where pump still circulates without cavitating. If pump sucks air, add minimum amount of make-up water to maintain circulation.

3. In order to clean the entire system, including cooling tower, sump tank, pump piping, and all associated equipment on tower while system is in operation, you must first determine the tonnage of your cooling tower. Documentation supplied with your tower or a nameplate on the tower should indicate the cooling capacity, in tonnage.

4. Please refer to the Chart on the following page to compute the proper amount needed.

5. Slowly add this quantity of DYNAMIC ECO-DESCALER to the sump tank over at least a two hour period.

6. Circulation time should be at least five hours during which all equipment should be online. However, anytime thereafter the make-up water can be turned on and the bleed-off opened and set to remove all of the dissolved solids from the system.

7. In order to purge all insolubles from closed circuit systems, it is suggested that after circulation; the drain valve should be opened and make-up water added until all water in system is clear. Close drain and establish proper bleed-off and make-up.

8. When convenient, it is recommended that the sump tank be drained and flushed and that the strainer screen be removed and inspected for any insolubles.
 

  Heat Exchangers

Heat exchangers in many manufacturing facilities are very crucial in everyday operations. Heat exchangers are designed to heat in the form of kinetic energy from one liquid to another. And while transferring heat, the heat exchanger, over a period of time will collect lime, scale and rust on the waterside of the Exchanger. With, DYNAMIC ECO-DESCALER, you do not have to dismantle or remove the unit from your operations.
You may want to install a system, which will inject DYNAMIC ECO-DESCALER into your water supply on a regular basis for your cooling tower, chiller, or your closed loop water system. This procedure will eliminate down time in your everyday operations while cleaning out your exchanger. If you just intended to clean out the heat exchanger, you still do not have to dismantle or remove the exchanger from your operations.

INSTRUCTIONS FOR DYNAMIC ECO-DESCALER CLEANING

1. By-pass heat exchanger from operation.

2. Remove the existing water in the exchanger. This MUST be done, to insure proper results.

3. Disconnect the water in/out connections from exchanger.

4. Attach the necessary hoses to the in/out connections on the exchanger to a circulating pump. Refer to our chart for necessary circulation time and the amount of DYNAMIC ECO-DESCALER to be used.

5. Once the circulation has been completed, flush the exchanger with water to remove any insolubles.


Please Refer to the Charts on the Following Pages for Proper Amount of DYNAMIC ECO-DESCALER to be used, and the Circulation Times.

Please Feel Free to Call Our Office with any Questions!

Request: Dynamic Eco-Descaler .pdf file

                   Comparitive Corrosion Analysis .pdf file

Back to Chemical Products


Dynamic Eco-Descaler



Site Designed and Maintained By Panther Marketing & Design