Web Site Navigation
Strain Measurement Instruments - Stress Measurement Instruments Directory
|
The Strain Measurement Instruments - Stress Measurement Instruments Directory section from Process Controls and Instrumentation Buyers Guide is a comprehensive directory resource. The Strain Measurement Instruments - Stress Measurement Instruments Directoryoffers a comprehensive range of strain measurement and stress measurement instruments from leading manufacturers. |
|
Stress Measurement Instruments |
|
|
Stress Analysis Data System 5000 Stress, Analysis, Data, System, 5000The Measurements Group revolutionized strain measurement in 1981 with the introduction of System 4000 Stress Analysis Data System, a complete hardware/software approach to data acquisition, reduction and presentation for strain gauges and related sensors for stress analysis testing. |
|
|
Transducer Class Strain Gauges Transducer-Class Strain Gauges are a select group of gauge |
|
|
Residual Stress Measurement |
|
|
M-Line Strain Gauge Accessories |
|
|
Basic Strain Gauge (Gage) Instrumentation |
|
|
Model 2000 Analog-to-Digital Converter |
|
|
Model V/E-40 Strain Gauge Simulator |
|
|
System 6000 Featuring StrainSmart Software |
|
|
System 7000 |
|
|
StrainSmart Software for Stress Analysis Testing |
|
|
Strain Measurement Instruments |
|
|
Model P3 Strain Indicator & Recorder The P3 Strain Indicator is a portable, battery- operated instrument capable of simultaneously accepting four inputs from quarter-, half-, and full-bridge strain-gauge circuits, including strain-gauge-based transducers. |
|
|
Model 1550A Strain Indicator Calibrator Strain Indicator Calibrator Vishay Model 1550A is atrue Wheatstone-bridge simulator, the 1550A Strain Indicator Calibrator presents known and repeatable resistance changes to the input of the indicator. |
|
|
Strain Gauge (Bridge) Input Process Indicator The DIS878 and DlS978 provide a display, optional isolated DC output voltage or current proportional to the output of a strain gauge bridge, and optional alarm setpoints. All Wilkerson products are designed with RFI filters and lightning protection to reduce susceptability to electrical noise and |
|
|
Strain Gauge (Bridge) Input Field Rangeable DIN Rail Mounted Isolated Transmitter The DM4051 provides an isolated voltage or current output proportional to a strain gauge (bridge) input. Measurement of output from load cells, pressure transmitters, and strain gauge sensors. Eliminates ground loops and common mode signals. Single-unit replacement module provides all normal input and output ranges. |
|
|
Strain Gauge (Bridge) Input Single Alarm The MM1500 monitors the DC input signal from a strain gauge bridge and trips a dpdt, 5 A relay when the input exceeds the desired level. Normal operation has the relay energized for the non-alarm condition and de-energized for an alarm condition. This provides a fail-safe alarm condition for loss of power to the module. The alarm has a set of red/green LEDs to indicate alarm status. |















