Cabinet,Cooler,Selection

Cabinet Cooler Selection


Products
by Category:

 ACCUTHERM HEATERS
  Air Heaters
  Bore Heaters
  Container Heaters
  Custom Heaters
  Immersion Heaters

  Tubular Elements
 BALERS
  
2-Ram Baler
  
Auto Tie Baler
  
Closed Door Horizontal
  Dust & Can Baler
  Expanado Hopper Baler
  Heavy Duty Vertical Baler
  Scrap Metal Vertical Baler
 BIODEGRADABLE PAINT
 STRIPPER

  JEM Strip 427

 BRIQUETTING MACHINES
  
Briquetters
  
Briquette Pellet Press
  
Briquetting Process
  Elan B60
  Elan Hydrospeed
 CHEMICAL PRODUCTS
  
Chemical Products
 COATINGS - WATER BASED
  
Carbicote Strippable Coating
 CONCRETE & ASPHALT
 CLEANER
  
Concrete & Asphalt Cleaner
 CORONA TREATMENT
  Flexidyne
  Labdyne
  Multidyne
  Polydyne
 DESCALERS & CLEANERS
  Cleaners
  Degreasers
  Descalers
 EXAIR COMPRESSED AIR

  Adjustable Spot Cooler

  Amplifier Products
  Air Knives
  Air Jets & Nozzles
  Air Operated Conveyors
  Cabinet Coolers
  Industrial Housekeeping
  Vortex Tubes
 EXAIR STATIC CONTROL
  Ion Air Cannon
  Ion Air Gun
  Ion Air Jet
  Ionizing Bars
  Ionizing Point
  Standard Ion Air Knife
  Static Eliminator Basics
  Static Eliminators
  Static Meter
  Super Ion Air Knife
 HAUG STATIC CONTROL
  Haug Charging Generators
  Haug High V Transformers
  Haug Ionization Bar
  Haug Ionizers
  Haug Ionization Systems
  Haug Ionizing Air Blower
  Haug Ionizing Air Gun
  Haug Ionizing Air Bar EI-VS
  Haug Ionizing Air Bar EI-Ex
  Haug Static Elimination
  Haug Static Measuring
  Haug Static Testing
  Haug Uno Air Gate

 HEAT TRANSFER FLUIDS
  Systems
  Food Grade
  High Quality
  Low Pressure
 HOT STAMPING MACHINES
  Automated Assembly Sys.
  Heat Transfer Decorating
  Hot Stamping Machines
  OIL SKIMMERS
  
Adjustable Lift Rate
  
Belt Type
  
"MAXI-Skimmer"
  "MINI-Skimmer"
  Tube Type
  Wheel Type

 PLASTIC FALW REPAIR
  Plastic Flaw Repair Products
 PRINTING PRESS EQUIP.
  Registration Control
  High Speed Card Insertion
  Variable Applicators
  Video Web Inspection
  Hurletron - Product Overview
 ROLL HANDLING SYSTEMS
  Reel Handlers
  Tilt-Lock - Core Chucks
  Tilt Lock - Systems
 ULTRASONIC CLEANING

  Ultrasonic Cleaning
  Mould Cleaners
 WASTE COMPACTION
  Kenbay


.

  Tech Sales Co. - EXAIR Product
  Cabinet Cooler Selection

Cabinet,Cooler,Applications
Cabinet Cooler Selection

Selecting the Right Cabinet Cooler
EXAIR Cabinet Coolers are available with or without thermostat control. The continuous coolers (Model 4200 and 4700 series) are recommended when constant cooling and a constant positive purge are desirable. The thermostatically controlled systems (Model 4300 and 4800 series) save air by activating the cooler only when internal temperatures approach critical levels. The adjustable thermostat is factory set at 95°F (35°C). Thermostatic systems are recommended where heat load fluctuates and continual purge is not required.

All EXAIR Cabinet Cooler Systems contain a 5 micron Automatic Drain Filter for the compressed air supply and a Cold Air Distribution Kit to circulate the cold air throughout the enclosure.

Special Cabinet Coolers
EXAIR manufactures special NEMA 4, 4X and 12 Cabinet Coolers suited to specific environmental requirements:
High Temperature Cabinet Coolers
for ambients of 125° to 200°F (52° to 93°C) are available. Internal components can withstand high temperatures (like those near furnaces, ovens, etc.). 
 

Non-Hazardous Purge Cabinet Cooler
are ideal for dirty areas where contaminants might normally pass through small holes or conduits.  Under normal conditions the NHP Cabinet Cooler System provides a slight positive pressure in the enclosure by passing 1 SCFM (28 SLPM) of air through the cooler.  When the thermostat detects high temperature, it energizes the solenoid valve to pass full line pressure to the Cabinet Cooler, giving it full cooling capability. 

 
Cabinet Cooler Systems with a 2800 Btu/hr. (706 Kcal/hr.) capacity are available.  They are ideal for applications where the heat load is extremely high.

If you have special requirements, please contact an Application Engineer to discuss the application.

Environmental Considerations

NEMA 12 Cabinet Coolers (dust-tight, oil-tight) are ideal for general industrial environments where no liquids or corrosives are present.

NEMA 4 Cabinet Coolers (dust-tight, oil-tight, splash resistant, indoor/outdoor service) incorporate a low pressure relief valve for both the vortex tube and cabinet air exhaust. This valve closes and seals when the cooler is not operating, to maintain the integrity of a NEMA 4 enclosure. 

NEMA 4X Cabinet Coolers offer the same protection as NEMA 4, but is constructed of 304 stainless steel for service in corrosive environments.

Specifications
Cabinet Cooler Specifications
NEMA 12
(Dust, oil resistant)
Model # Capacity
Btu/hr.
Capacity
Kcal/hr.
Thermostat
Control
4208 550 139 No
4225 1700 428 No
4230 2000 504 No
4308 550 139 Yes
4325 1700 428 Yes
4330 2000 504 Yes
NEMA 4
(Splash resistant)
4708 550 139 No
4725 1700 428 No
4730 2000 504 No
4808 550 139 Yes
4825 1700 428 Yes
4830 2000 504 Yes
NEMA 4X
(Corrosion resistant)
4708SS 550 139 No
4725SS 1700 428 No
4730SS 2000

504

No
4808SS 550

139

Yes
4825SS 1700

428

Yes
4830SS 2000

504

Yes
 
How to Calculate Heat Load for your Enclosure
To determine the correct model for your application, it is first necessary to determine the total heat load to which the control panel is subjected. This total heat load is the combination of two factors — heat dissipated within the enclosure and heat transfer from outside into the enclosure.

To Calculate Btu/hr.

  1. First, determine the approximate watts of heat generated within the enclosure.  Watts x 3.41 = Btu/hr.
  2. Then, calculate outside heat transfer as follows:
    a. Determine the area in square feet exposed to the air, ignoring the top of the cabinet.
    b. Determine the temperature differential between maximum surrounding temperature and desired internal temperature. Then, using the Temperature Conversion Table (below), determine the Btu/hr./ft.2 for that differential. Multiplying the cabinet surface area times Btu/hr./ft.2 provides external heat transfer in Btu/hr.
  3. Add internal and external heat loads for total heat load.
Temperature Conversion Table
Temperature 
Differential °F
Btu/hr./ft2
5 1.5
10 3.3
15 5.1
20 7.1
25 9.1
30 11.3
35 13.8
40 16.2
Example:

Internal heat dissipation: 471 Watts or 1606 Btu/hr.

Cabinet area: 40 ft.2

Maximum outside temperature: 110°F

Desired internal temperature: 95°F

The conversion table (above) shows that a 15°F temperature differential inputs 5.1 Btu/hr./ft.2

40 sq. ft. x 5.1 Btu/hr./ft.2 = 204 Btu/hr. external heat load.

Therefore, 204 Btu/hr. external heat load plus 1606 Btu/hr. internal heat load = 1810 Btu/hr. total heat load or Btu/hr. refrigeration required to maintain desired temperature.

In this example, the correct choice is a 2000 Btu/hr. Cabinet Cooler System. Choose a Cabinet Cooler model by determining the NEMA rating of the enclosure (type of environment), and with or without thermostat control.

 

Need Help Sizing EXAIR Cabinet Coolers?

Fill out our online Cabinet Cooler Sizing Guide Form and we'll
contact you with our recommendation right away

- OR -

For answers NOW, call our Tech Sales at (416) 410-1313

 
To Calculate Kcal/hr.
  1. First, determine the approximate watts of heat generated within the enclosure.  Watts x .86 = Kcal/hr.
  2. Then, calculate outside heat transfer as follows:
    a. Determine the area in square meters exposed to the air, ignoring the top of the cabinet.
    b. Determine the temperature differential between maximum surrounding temperature and desired internal temperature. Then, using the Metric Temperature Conversion Table (below), determine the Kcal/hr./m2 for that differential. Multiplying the cabinet surface area times Kcal/hr./m2 provides external heat transfer in Kcal/hr.
  3. Add internal and external heat loads for total heat load.
Temperature Conversion Table
(METRIC)
Temperature 
Differential °C
Kcal/hr./m2
3 4.5
6 9.7
9 15.1
12 21
15 27
18 34
21 41
Example:

Internal heat dissipation: 471 Watts or 405 Kcal/hr.

Cabinet area: 3.7m2

Maximum outside temperature: 44°C

Desired internal temperature: 35°C

The conversion table (above) shows that a 9°C temperature differential inputs 15.1 Kcal/hr./m 2 .

3.7m 2 x 15.1 Kcal/hr./m 2 =56 Kcal/hr. external heat load.

Therefore, 56 Kcal/hr. external heat load plus 405 Kcal/hr. internal heat load = 461 Kcal/hr. total heat load or Kcal/hr. refrigeration required to maintain desired temperature.

In this example, the correct choice is a 504 Kcal/hr. Cabinet Cooler System. Choose a Cabinet Cooler model by determining the NEMA rating of the enclosure (type of environment), and with or without thermostat control.

 
Dimensions

Model #'s
NEMA 12
4008
4208
4308

Model #'s
NEMA 12
4025
4030
4225
4230
4325
4330
Model #'s
NEMA 4   NEMA 4X
4608 4608SS
4708 4708SS
4808 4808SS
Model #'s
NEMA 4   NEMA 4X
4625 4625SS
4630 4630SS
4725 4725SS
4730 4730SS
4825 4825SS
4830 4830SS
 
NEMA 4, 4X and 12 Cabinet Coolers are available in many cooling capacities for
large and small control panels.
Other Factors
Filtration:
EXAlR Cabinet Cooler Systems include a 5 micron automatic drain water and dirt filter. This filter is critical for protection of electronics from water in the compressed air line. If oil is present in the compressed air supply, the addition of a coalescing (oil removal) filter, such as EXAlR Model 9005, is recommended.

Systems for continuous operation include a Cabinet Cooler, distribution kit and filter.

Cold Air Distribution Kit:
The kit includes a length of flexible vinyl tubing used to direct the cold air for circulation, or to hot spots. Tubing connectors and adhesive backed clips to hold the tubing in place are provided.
Humidity:
For a continuous operating Cabinet Cooler, relative humidity inside the enclosure stabilizes at 45%. No moisture condenses inside the enclosure. (The enclosure must be sealed to prevent condensation.)
Inlet Air Temperature:
Cabinet Cooler Systems provide a 50°F (28°C) temperature drop from supply air temperature when the inlet pressure is 100 PSlG (6.9 BAR). Elevated inlet temperature will produce a corresponding rise in cold air temperature and reduction in cooling capacity. Low air pressures will also reduce the cooling capacity.
Mounting:
The Cabinet Cooler mounts to the enclosure through a drilled hole or electrical knockout. The NEMA 12 Cabinet Coolers may be mounted on the top or side of the panel. NEMA 4 and 4X Cabinet Coolers must be mounted on the top of the panel.
Solenoid Valve and Thermostat:
Cabinet Cooler Systems with thermostat control include a solenoid valve and thermostat that limit the flow of compressed air to only when cooling is needed. The solenoid valve is rated 120V, 60 Hz or 110V, 50 Hz. It is UL Listed, CSA Certified.
The thermostat is factory set at 95°F (35°C). It will normally hold ±2°F
(1°C) inside the cabinet. It is rated 120V, 50/60 Hz and is UL Recognized, CSA Certified.

Cabinet Coolers | Cabinet Cooler Selection | Cabinet Cooler Systems
Cabinet Cooler | Sizing Guide | Cabinet Cooler Applications
Cabinet Cooler Installation & Maintenance

PDF Download Brochure | Price List Link


Cabinet Cooler Selection



Site Designed and Maintained By Panther Marketing & Design