Electrical
Power Measurement
|
|
A2000
Multifunction 3-Phase Power Meter
|
|
Input:
|
0-1A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz
|
Output:
|
Programmable
4 Analog
2 Digital Pulse
2 Relays
|
|
- Display 4 Variables
- Up to 4 Analog
and 2 Pulse Outputs
- Data Logging of
any of 37 Values
- 2 Relay Outputs
- Alarm Contacts
Triggered on any Setpoint
- Includes Measurement
& Configuration Software
- MODBUS / LONBUS
/ PROFIBUS Versions
- 24-60 VAC/VDC
or 85-230 VAC/VDC Powered
|
More Information Technical
Data
|
|
A210
Multifunction 3-Phase Power Meter
|
|
Input:
|
0-1 A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz
|
Output:
|
Programmable
Digital Pulse
Relay
|

|
|
EMMOD
201
|
Specifications
Instructions
EMMOD
MODBUS
|
|
M
563 Power & Current Transducer
|
|
Input:
|
0-1 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50 or 60 Hz
|
Output:
|
0-20 mA, 4-20 mA
0-1 V to 0-10 V
2-10 V
|

|
- 3 Analog Outputs
- Measures any
Three: P, Q or S, I ~, U ~ (RMS), cos j, sin j,
LF, PF, QF, f
- RS 232 PC Programming
Interface
- 24-60 VAC/VDC
or 85-230 VAC/VDC Powered
|
Specifications
Instructions
|
|
DME
424 & DME 442 Energy Transducers
|
|
Input:
|
0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
|
Output:
|
0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
Open Collector Pulse
|
|
-
DME
424 with 2 analog and 4 digital pulse outputs
-
DME
442 with 4 analog and 2 digital pulse outputs
- Measures P,
Q or S, I ~, U ~ (RMS), cos j, sin j, LF, PF,
QF, f
- Data Logging
Function
- RS 232 PC Programming
Interface
- 24-60 VAC/VDC
or 85-230 VAC/VDC Powered
|
Specifications
Instructions
|
|
DME
406 Energy Transducer
|
|
Input:
|
0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
|
Output:
|
Profibus DP
|
|
- Measures P,
Q or S, I ~, U ~ (RMS), cos j, sin j, LF, PF,
QF, f
- Data Logging
Function
- RS 232 PC Programming
Interface
- RS485 with Profibus
DP output
- 24-60 VAC/VDC
or 85-230 VAC/VDC Powered

|
Specifications
Instructions
|
|
P
530 Active Power & Q 531 Reactive Power Transducers
|
|
Input:
|
0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
100-690 V
50/60 Hz
|
Output:
|
0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V
|
|
-
3-Phase
with Balanced or Unbalanced Load
-
Sinusoidal
Input
- Available as Measuring
Source Powered to 230 V
- 24-60 VAC/VDC
or 85-230 VAC/VDC Powered
|
Specifications
Instructions
|
|
I 538 AC Current
Transducer
|
|
Input:
|
0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
50/60 Hz
|
Output:
|
0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
|
|
-
Sinusoidal
Input
- Available
as Measuring Source Powered to 230 V
- 24-60
VAC/VDC or 85-230 VAC/VDC Powered
|
Specifications
Instructions
|
|
|
I
542 AC Current Transmitter
|
|
Input:
|
0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
50/60 Hz
|
Output:
|
0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
|
|
|
|
Specifications
Instructions
|
|
I
552 True RMS AC Current Transducer
|
|
Input:
|
0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
50/60 or 400 Hz
|
Output:
|
0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
|
|
-
Sine,
Rectangular or Distorted Wave Forms
- Available
as Measuring Source Powered to 230 V
- 24-60
VAC/VDC or 85-230 VAC/VDC Powered
|
Specifications
Instructions
|
|
U
539 AC Voltage Transducer
|
|
Input:
|
0-50 V to 0-600 V
50/60 Hz
|
Output:
|
0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V
|
|
-
Sinusoidal
Input
- Available
as Measuring Source Powered to 230
V
- 24-60
VAC/VDC or 85-230 VAC/VDC Powered
|
Specifications
Instructions
|
|
|
|
U
543 AC Voltage Transducer
|
|
Input:
|
0-20 V to 0-600 V
50/60 Hz
|
Output:
|
0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V
|
|
|
|
Specifications
Instructions
|
|
|
U
553 True RMS AC Voltage Transducer
|
|
Input:
|
0-20 V to 0-690 V
50/60 or 400 Hz
|
Output:
|
0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V
|
|
-
Sine,
Rectangular or Distorted Wave Forms
- 24-60
VAC/VDC or 85-230 VAC/VDC Powered
|
Specifications
Instructions
|
|
|
U
554 True RMS AC Voltage Transducer
|
|
Input:
|
0-20 V to 0-690 V
50/60 or 400 Hz
|
Output:
|
0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V
|

|
|
|
Specifications
Instructions
|
|
F
534 Frequency Transducer
|
|
Input:
|
10 V to 690 V
10 to 1500 Hz
|
Output:
|
0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V
|
|
-
Sine,
Rectangular or Distorted Wave Forms
- Available as Measuring
Source Powered to 230 V
- 24-60 VAC/VDC
or 85-230 VAC/VDC Powered
|
Specifications
Instructions
|
|
F
535 Frequency Difference Transducer
|
|
Input:
|
10 V to 690 V
10 to 1500 Hz
|
Output:
|
0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V
|

|
- Measure Δf
Between 2 Synchronized Supplies
-
Sine,
Rectangular or Distorted Wave Forms
- Available as Measuring
Source Powered to 230 V
- 24-60 VAC/VDC
or 85-230 VAC/VDC Powered
|
Specifications
Instructions
|
|
G
536 Phase Angle Transducer
|
|
Input:
|
1 or 5 A
10 V to 690 V
16 to 400 Hz
0.5 cap. 1.ind. 0.5 cos Φ
|
Output:
|
0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V
|
|
- Measure Single
or 3-Phase Balanced
-
Sine,
Rectangular or Distorted Wave Forms
- Available as Measuring
Source Powered to 230 V
- 24-60 VAC/VDC
or 85-230 VAC/VDC Powered
|
Specifications
Instructions
|
|
G
537 Phase Angle Difference Transducer
|
|
Input:
|
10 V to 690 V
50 or 60 Hz
|
Output:
|
0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V
|

|
- Measure
ΔΦ Between 2 Synchronized
Supplies
-
Sine,
Rectangular or Distorted Wave Forms
- Available
as Measuring Source Powered to 230 V
- 24-60
VAC/VDC or 85-230 VAC/VDC Powered
|
Specifications
Instructions
|
|
Back
To API-Camille Bauer
|
|