Electrical,Power,Measurement
Quality • Performance • Price • 1972-2003


Electrical Power Measurement

Products
Minco Products Inc.
Sensors, Heaters, Transmitters, Controllers, Flex-Circuits
• Minco Products Overview
• Flexible Heaters
• Temperature Sensors
• Temperature Transmitters
• Flex-Circuits
• Temperature Controllers
 
Mercotac Inc.
Rotating Electrical Connectors
•
Mercotac Products Overview
•
Rotating Electrical Connectors
Coaxial Series up to 3 conductors
Modular Series up to 8 conductors

• Product Specification Table
• Accessories

Receptacles and disconnects

• Boot Kits

Rubber Safety Boots

 
Absolute Process Instruments
Signal Conditioners & Alarms
•
API Product Overview
•
AC Input Modules
• Bridge Input Modules
• Current Sensors
• DC Input Alarm Trips
• DC-DC Transmitters
• Frequency Modules
• Loop Power Supplies
• Loop Powered Isolators
• Math Modules & Valve
   Positioner
• Module Accessories
• Potentiometer Input Modules
• RTD Input Modules
• Thermocouple Input Modules
 
API-Camille Bauer
• API-Camille Bauer Overview
•
Signal Conditioners
• Temperature Transmitters
• KINAX Position Transducers
• Electrical Power Measurement
 
Exergen Corporation
Infrared Sensors & Scanners
• Exergen Products Overview
•
IRt/c™ Infrared Thermocouples
• Smart IRt/c™ Thermocouple
• Micro IRt/c™ Thermocouples
• IRt/c™ Reference Pages

• D-Series Infrared Scanner
• DX-Series Infrared Scanner
• E-Series Infrared Scanner
• SnakeEye Infrared Switch

 
Love Controls
Sensors, Controls, Relays, Transmitters, Recorders
•
Love Products Overview
• Temperature/Process Controls
• Digital Indicators
• Temperature Sensors
• Output Devices
• Transmitters & Alarms
• Data Acq./Recorders
• Transmitters& Alarms
•
AC Current Indicators
 
Dynalco Controls
Speed Sensors
• Dynalco Products Overview
• Standard Magnetic Pickups
• Powered Pickups
• Miniature Magnetic Pickups
• Intrinsically Safe Magnetic Pickups
• Power Source Magnetic Pickups
•
Cable Assemblies


Instruments & Tachometers

• Tachometers
• Speed Switch
•
General Purpose Meters

• Temperature Indicators
• Universal Scanner

 
Cecomp Electronics
Digital Pressure Gauges
• Cecomp Products Overview
•
F4B & F4BBL Series 
• F4AD & F4ADBL Series
• F4L Series
• F4DR & F4DRBL Series
•
DPG1000B & DPG1000BBL
• ARM760 Series
• DPG1000AD & DPG1000ADBL
• DPG1000L Series
• DPG1000DR & DPG1000DRBL
• DPG1000ADA Series
• DPG1000DAR Series
• Tech Info, Accessories
 
Beede Instruments
• Beede Products Overview
•
Analog Panel Meters
•
Analog Meter Relays

 
Web Site
Useful Web Site Tools


  Electrical Power Measurement

A2000 Multifunction 3-Phase Power Meter

Input:

0-1A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz

Output:

Programmable
4  Analog
2  Digital Pulse
2  Relays
  • Display 4 Variables
  • Up to 4 Analog and 2 Pulse Outputs
  • Data Logging of any of 37 Values
  • 2 Relay Outputs
  • Alarm Contacts Triggered on any Setpoint
  • Includes Measurement & Configuration Software
  • MODBUS / LONBUS / PROFIBUS Versions
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
More Information    Technical Data

A210 Multifunction 3-Phase Power Meter

Input:

0-1 A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz

Output:

Programmable
Digital Pulse
Relay

  • 3 Variable Display
  • Open Collector Alarm Relay and Pulse Outputs
  • Data Logging and MODBUS with Option EMMOD 201
  • 19 Types of Measurements
  • Hi/Lo Electrical Rates
  • 1/4 DIN size
  • Includes RS-232 Measurement & Configuration Software

  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered

  EMMOD 201

Specifications   Instructions   EMMOD  MODBUS

 

M 563 Power & Current Transducer

Input:

0-1 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50 or 60 Hz

Output:

0-20 mA, 4-20 mA
0-1 V to 0-10 V
2-10 V

  • 3 Analog Outputs
  • Measures any Three: P, Q or S, I ~, U ~ (RMS), cos j, sin j, LF, PF, QF, f
  • RS 232 PC Programming Interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

 

DME 424 & DME 442 Energy Transducers

Input:

0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz

Output:

0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
Open Collector Pulse

  • DME 424 with 2 analog and 4 digital pulse outputs

  • DME 442 with 4 analog and 2 digital pulse outputs

  • Measures P, Q or S, I ~, U ~ (RMS), cos j, sin j, LF, PF, QF, f
  • Data Logging Function
  • RS 232 PC Programming Interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

 

DME 406 Energy Transducer

Input:

0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz

Output:

Profibus DP

  • Measures P, Q or S, I ~, U ~ (RMS), cos j, sin j, LF, PF, QF, f
  • Data Logging Function
  • RS 232 PC Programming Interface
  • RS485 with Profibus DP output
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

P 530 Active Power & Q 531 Reactive Power Transducers

Input:

0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
100-690 V
50/60 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V

  • 3-Phase with Balanced or Unbalanced Load

  • Sinusoidal Input

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

I 538 AC Current Transducer

Input:

0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
50/60 Hz

Output:

0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
  • Sinusoidal Input

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications   Instructions

 

I 542 AC Current Transmitter

Input:

0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
50/60 Hz

Output:

0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
  • Sinusoidal Input

  • Powered from Measuring Source

Specifications   Instructions

I 552 True RMS AC Current Transducer

Input:

0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
50/60 or 400 Hz

Output:

0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
  • Sine, Rectangular or Distorted Wave Forms

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

SINEAX Voltage Transducers

U 539  AC Voltage Transducer

Input:

0-50 V to 0-600 V
50/60 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

  • Sinusoidal Input

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

 

U 543 AC Voltage Transducer

Input:

0-20 V to 0-600 V
50/60 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

  • Sinusoidal Input

  • Powered from Measuring Source

Specifications   Instructions

 

U 553 True RMS AC Voltage Transducer

Input:

0-20 V to 0-690 V
50/60 or 400 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

  • Sine, Rectangular or Distorted Wave Forms

  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

 

U 554 True RMS AC Voltage Transducer

Input:

0-20 V to 0-690 V
50/60 or 400 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

  • Sine, Rectangular or Distorted Wave Forms

  • Special Version to Allow Zero Offset

  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

F 534  Frequency Transducer

Input:

10 V to 690 V
10 to 1500 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V

  • Sine, Rectangular or Distorted Wave Forms

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

 

F 535 Frequency Difference Transducer

Input:

10 V to 690 V
10  to 1500 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V

  • Measure Δf Between 2 Synchronized Supplies
  • Sine, Rectangular or Distorted Wave Forms

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

G 536 Phase Angle Transducer

Input:

1 or 5 A
10 V to 690 V
16 to 400 Hz
0.5 cap. 1.ind. 0.5 cos Φ

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V

  • Measure Single or 3-Phase Balanced
  • Sine, Rectangular or Distorted Wave Forms

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

 

G 537 Phase Angle Difference Transducer

Input:

10 V to 690 V
50 or 60 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V

  • Measure ΔΦ Between 2 Synchronized Supplies
  • Sine, Rectangular or Distorted Wave Forms

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions
Back To API-Camille Bauer

Tel: 1-800-794-5883
Fax: 1-800-830-7122
Electrical Power
Measurement

Site Designed And Maintained By Panther Marketing And Design