Air
Amplifier Compressed Air Consumption
(Based on gap of 0.002)
Air Amplifier Compressed
Air Consumption in SCFM
|
Inlet
Pressure
|
AM10
|
AM20
|
AM40
|
AM75
|
AM125
|
|
20
PSIG
|
2.2
|
4.3
|
8.0
|
16.5
|
65.0
|
|
40
PSIG
|
3.4
|
6.1
|
11.3
|
23.2
|
90.0
|
|
60
PSIG
|
4.3
|
7.5
|
15.0
|
29.7
|
119.5
|
|
80
PSIG
|
4.9
|
9.3
|
19.3
|
37.0
|
137.5
|
|
100
PSIG
|
5.8
|
11.0
|
25.1
|
44.0
|
150.0
|
|
120
PSIG
|
6.1
|
11.8
|
26.0
|
47.0
|
152.0
|
Air
Amplifier Ducting
Both the inlet (vacuum intake) and discharge ends of the
Air Amplifier
from NEX FLOW Technologies
may be ducted for light material and fume conveying applications.
Care must be taken to avoid unnecessary restrictions that
will cause back pressure or suction resistance that will
reduce performance levels. Keep back pressure and resistance