General,Purpose,Nontoxic,High,Quality,Heat,Transfer,Fluid

General Purpose Nontoxic
High Quality Heat Transfer Fluid


  Index | Products | About Us | Feedback | Contact Us

Products
 AIR/GAS FLOW METERS
  Thermal Mass Flow Meter
  Thermal Flow/Level Switch
 ACCUTHERM HEATERS
  Air Heaters
  Bore Heaters
  Container Heaters
  Custom Heaters
  Immersion Heaters

  Tubular Elements
 BALERS
  2-Ram Baler
  
Auto Tie Baler
  
Closed Door Horizontal
  Dust & Can Baler
  Expanado Hopper Baler
  Heavy Duty Vertical Baler
  Scrap Metal Vertical Baler
 CABINET COOLERS
  Cabinet Cooler Compress Air
  Filter Ventilator Systems
  Model 60A
  Model 150C
  Model 500C
  Model 1000A
  Model 1400
 CHEMICAL PRODUCTS
  Aluminum Cleaner
  Asphalt/Concrete Cleaner
  Defoamers
  Degreasers
  Food Grade Degreasers
  Heat Transfer Fluids
  Multi-Purpose Cleaners
  Oxidation Prevention
  Paint Strippers
  Rust Prevention
  Rust Remover - ScaleGone
 COMPRESSED AIR
  Air Amplifiers
  Air Conveying System
  Air Knives
  Air Jets Blow Off System
  Air Nozzles
  Cabinet Coolers
  Industrial Housekeeping
  Ionizing Air Knife (Air-Blade)
  Quality Air Wipes
  Spot Cooling - Cold Guns
  Vortex Tubes
 CORONA TREATMENT
  Bottledyne
  Flexidyne
  Labdyne
  Multidyne
  Plasmadyne
  Polydyne
 DESCALERS & CLEANERS
  Dynamic Descaler
 FILTRATION EQUIPMENT
  Rotary Drum Filter
  For Liquid-Solids Separations
 STATIC CONTROL
 HAUG
  Charging Generators
  High V Transformers
  Ionization Bar
  Ionizers
  Ionization Systems
  Ionizing Air Blower
  Ionizing Air Gun
  Ionizing Air Bar EI-VS
  Ionizing Air Bar EI-Ex
  Static Control Systems

  Static Elimination
  Static Measuring
  Static Testing
  Uno Air Gate
 OIL SKIMMERS
  Adjustable Lift Rate
  
Belt Type
  
"MAXI-Skimmer"
  "MINI-Skimmer"
  Tube Type
  Wheel Type
 PLASTIC FLAW REPAIR
  Plastic Flaw Repair
 PRINTING PRESS EQUIP.
  Registration Control
  High Speed Card Insertion
  Variable Applicators
  Video Web Inspection
  Hurletron - Overview
 ROLL HANDLING SYSTEMS
  Reel Handlers
  Tilt-Lock - Core Chucks
  Tilt Lock - Systems
 STRIPPABLE COATINGS
  Carbicote Coating
 ULTRASONIC CLEANING
  Ultrasonic Cleaners
  Ultrasonic Cleaning
 WASTE COMPACTION
  Kenbay
 WEB & SHEET CLEANING
  Web Cleaners

.



Add Me to your mail list so I can be kept informed about new products.

April Newsletter

www.tech-sales.com
  General Purpose Nontoxic Heat Transfer Fluid
  High Quality Heat Transfer Fluid

General Purpose Nontoxic
High Quality Heat Transfer Fluid

AN ECONOMICAL GENERAL PURPOSE FLUID FOR OPEN AND CLOSED LOOP LIQUID PHASE HEATING SYSTEMS.

MultiTherm IG-2 ® is a Nontoxic High Quality Heat Transfer Fluid for use in closed loop, liquid phase heating systems up to 600°F and in open systems up to 400°F.

MultiTherm IG-2 ® has been successfully used in a variety of chemical process industry, it is used in central hot oil systems for heating all types of process equipment. In asphalt storage facilities, the fluid is used for line tracing and tank heating. In industries laundries MultiTherm IG-2 ® provides higher throughput with a great degree of safety in flat work ironies.

DURABLE

Open Systems
Oxidation and fluid boil-off are major problems when using organic heat transfer fluids in hot open systems. Oxidation produces organic acids, which react and create deposits. The rate of boil-off an oxidation are dependent of the fluid vapor pressure. The higher the vapor pressure, the greater rate of oxidation and fluid boil-off. MultiTherm IG-2 ® has exceptionally low vapor pressure, and as a result its service life is significantly longer under these severe conditions.

Closed Loop Systems
Closed loop, liquid phase heat transfer systems often operate for extended periods of time with little or no problems. However, equipment malfunctions such as circulating pump failures, bypass valve malfunctions, and cracked heater tubes do occur and can put extra stress on the heat transfer fluid. If the fluid has been in service for a period of time, and especially if it has been exposed to air at high temperature, these malfunctions can cause rapid degradation and require immediate replacement to prevent further equipment problems. MultiTherm IG-2 ® is a highly refined product with proven resistance to oxidation and thermal breakdown. It can take the stress without requiring premature replacement.

HIGH FLASH POINT

In certain applications, local, state or federal regulations may require that the thermal fluid system operate below the fluid flash point. This can result in the need for greater heat transfer surface area (more expensive equipment) to achieve required heat loads. MultiTherm IG-2 ® has one of the highest flash points of any heat transfer fluid (440°F / 227°C) which provides maximum system efficiency under these conditions.

LOWER COSTS

Reduced Equipment Costs
Incorporating MultiTherm IG-2 ® in a system during the design phase can reduce equipment costs. Its extremely low vapor pressure eliminates the need for pressurized expansion tanks to prevent pump cavitation and can allow specification of less expensive, low pressure piping and process equipment. VOC emissions are not normally a problem with MultiTherm IG-2 ® since system pressures are low and fluid vapor pressure is not significant.

Reduced Maintenance Costs
MultiTherm IG-2
® is based on a parrafinic oil that coats all system surfaces with a protective fluid film. This film provides outstanding lubricity for moving parts and also helps protect components from corrosion.

PHYSICAL CHARACTERISTICS

MultiTherm IG-2 ®

Chemical Type

Solvent, Refined Parrafinic Distillate

Appearance

Clear, Pale Golden

Odor

Faint Oily

Pour Pint, ASTM D97

0°F                            (-18°C)

Density @ 60°F / 16°C

7.23 lb/gal

Flash Point, coc, ASTM D92

440°F                           (227°C)

Fire Point, coc, ASTM D92

500°F                            (260°C)

Autoignition Temperature, ASTM D2155

700°F                            (371°C)

Atmospheric Boiling Point (10%) ASTM D1160

780°F                            (416°C)

Average Molecular Weight

440

Maximum Film Temperature

650°F                             (343°C)

Maximum Recommended Operating Temperature

600 F/316 C

Pumpable, Centrifugal @ 2000 centipoise

5°F                                 (-15°C)

Heat of Vaporization @ 600°F / 316°C

85 BTU/lb                   (198 kJ/kg)

Heat of Combustion

19,500 BTU/lb               (45.3 MJ/kg)

Coefficient of Thermal Expansion

0.00045/°F                    (0.0008/°C)


MultiTherm PG-1 | MultiTherm IG-2 | MultiTherm 503
Thermal Transfer Fluid | Process Cooling


  Index | Products | About Us | Feedback | Contact Us

General Purpose Nontoxic
High Quality Heat Transfer Fluid


Site Designed By Panther Marketing & Design